incl. MwSt. Versandkosten werden an der Kasse berechnet
Offers with a choice of IstaBreeze® i-500 wind generator in 12V or 24V
IstaBreeze® I-500 Wind Generator – 12 V or 24 V with I/HCC650 Hybrid Charge Controller
The IstaBreeze® I-500 is a brushless, three-phase wind generator in the 500W power class. It is available for 12V or 24V battery systems. The matching I/HCC650 hybrid charge controller is included with every version. A 4-meter tilting mast is available as an option.
Selection & Scope of Delivery
Battery voltage: 12 volts or 24 volts
Charge controller: I/HCC650 Hybrid – always included
Mast: none or 4-meter tilting mast
Delivery:
- 1 × IstaBreeze® I-500 wind generator at the selected voltage
- 1 × I/HCC650 hybrid charge controller
- If "4-meter tilting mast" is selected: an additional 1 x 4-meter tilting mast is included.
Other individual components of the turbine delivery scope are not listed individually in the present technical data.
Mast selection
without: The wind generator is delivered without a mast.
4-meter tilting mast: A 4-meter long tilting mast is also included in the scope of delivery.
Technical specifications – I-500 wind generator
| Technical information | 12 V | 24 V |
|---|---|---|
| performance class | 500 W | 500 W |
| Current rating according to datasheet (Max. power) | 35 A | 18 A |
| Open circuit voltage | 0-330VAC | 0-330VAC |
| Generator | Permanent magnet, brushless, direct drive | Permanent magnet, brushless, direct drive |
| phases | 3-phase | 3-phase |
| Generator weight | 6 kg | 6 kg |
| Start of loading | approx. 3 m/s | approx. 3 m/s |
| Main material | plastic / aluminum | plastic / aluminum |
| direction of rotation | Clockwise, viewed from the front | Clockwise, viewed from the front |
| Hub flange | Aluminium | Aluminium |
| rotor diameter | approx. 1,17 m | approx. 1,17 m |
| Rotor blade length | 57 cm | 57 cm |
| Rotor blade weight | approx. 210 g per sheet | approx. 210 g per sheet |
| Rotor blade material (data sheet information) | Carbon granules | Carbon granules |
| Maximum RPM | 1.900 U / min | 1.900 U / min |
| noise | 40 dB (A) | 40 dB (A) |
| test standards | EN 61000-6-1 / EN 61000-6-3 | EN 61000-6-1 / EN 61000-6-3 |
The designation 500 W describes the power class of the wind generator. The specifications 35 A (12 V) and 18 A (24 V) are current values from the data sheet and not power values in watts.
I/HCC650 Hybrid Charge Controller
The included I/HCC650 hybrid charge controller is used to charge suitable batteries with wind energy and also supports a solar input. It must be configured for the selected 12V or 24V system voltage.
- Hybrid function: Supports wind energy and additional solar energy.
- Solar input: Up to 150 W solar input power.
- Wind entrance: Up to 500 W wind power.
- Battery protection: Overcharge protection as well as short circuit and reverse polarity protection according to the device description.
- Braking function: Automatic braking function of the wind turbine and manual brake switch.
- System voltage: 12V or 24V, depending on the chosen variant.
Technical specifications – I/HCC650 Hybrid charge controller
| Technical information | 12 V | 24 V |
|---|---|---|
| Rated power of the charge controller | 650 W | 650 W |
| Input voltage range according to datasheet | 14,2-17 V | 24,6-28 V |
| battery voltage | 12 V | 24 V |
| Maximum solar input power | 150 W | 150 W |
| Maximum wind input power | 500 W | 500 W |
| Overcharge protection | 14,9 V | 29 V |
| No-load current | ≤ 0,2A | ≤ 0,2A |
| Recommended battery according to the data sheet | 12V / 150Ah or 12V / 200Ah | 24V / 75Ah or 24V / 100Ah |
| Max. wind turbine input current | 40 A | 20 A |
| Gross Weight | 620 gr | 620 gr |
| Dimensions | 200 × 115 × 60 mm | 200 × 115 × 60 mm |
The charge controller has a rated power of 650 W. The maximum wind input power is 500 W; the additional solar input is specified at a maximum of 150 W.
Battery information
The charge controller is designed for charging suitable batteries. Please check the compatibility and required system voltage of your battery before use. The charge controller is not intended for direct connection of electrical loads or a grid-tie inverter in place of a battery.
During installation, the manufacturer's connection instructions must be followed. The battery is connected to the charge controller before the wind generator and the solar panels.